Typical assembly (not a tested listing)

4-Hour Fire Rated Wood Stud Wall — 4 layers 5/8" Type C

Typical 4-hour fire-rated wood stud wall assembly. 2x4 wood studs at 24" o.c. with R-15 mineral wool batt, 4 layers of 5/8" Type C gypsum board each side. Illustrative example of typical construction — not a tested UL or GA listing. Use a listed design (UL Product iQ or GA-600) for construction documents.

2x4 wood studs at 24" o.c. with R-15 mineral wool batt, 4 layers of 5/8" Type C gypsum board each side