Typical assembly (not a tested listing)

2-Hour Fire Rated Wood Stud Wall — 2 layers 1/2" Type X

Typical 2-hour fire-rated wood stud wall assembly. 2x6 wood studs at 24" o.c. with R-19 fiberglass batt, 2 layers of 1/2" Type X gypsum board each side. Illustrative example of typical construction — not a tested UL or GA listing. Use a listed design (UL Product iQ or GA-600) for construction documents.

2x6 wood studs at 24" o.c. with R-19 fiberglass batt, 2 layers of 1/2" Type X gypsum board each side