Typical assembly (not a tested listing)

1-1/2 Hour Fire Rated Steel Stud Wall — 2 layers 5/8" Type X on resilient channels

Typical 1.5-hour fire-rated steel stud wall assembly. 2-1/2" steel studs at 24" o.c., 2 layers of 5/8" Type X gypsum board each side on resilient channels. Illustrative example of typical construction — not a tested UL or GA listing. Use a listed design (UL Product iQ or GA-600) for construction documents.

2-1/2" steel studs at 24" o.c., 2 layers of 5/8" Type X gypsum board each side on resilient channels