Typical assembly (not a tested listing)
3-Hour Fire Rated Shaft Wall — 2 layers 1" Type C
Typical 3-hour fire-rated shaft wall assembly. 3-5/8" CT studs at 24" o.c. with R-11 fiberglass batt, 2 layers of 1" Shaftliner gypsum board each side. Illustrative example of typical construction — not a tested UL or GA listing. Use a listed design (UL Product iQ or GA-600) for construction documents.
3-5/8" CT studs at 24" o.c. with R-11 fiberglass batt, 2 layers of 1" Shaftliner gypsum board each side