IBC Design 721.1(3) 27-1.1
1-Hour Fire Rated Wood I-joist (minimum I-joist depth 9-1/2" with a… — Minimum 0.019" thick resilient channel 16"…
IBC Table 721.1(3), Item 27-1.1: Wood I-joist (minimum I-joist depth 9-1/2" with a minimum flange depth of 1-5/16" and a minimum flange cross-sectional area of 1.95 square inches; minimum web thickness of 3/8") @ 24" o.c.. Ceiling: Minimum 0.019" thick resilient channel 16" o.c. (channels doubled at wallboard end joints), placed perpendicular to the joist and attached to each joist by 1-1/4" Type S drywall screws. Two layers of 1/2" Type X gypsum wallboard applied with the long dimension perpendicular to the resilient channels with end joints staggered. The base layer is fastened with 1-1/4" Type S drywall screws spaced 12" o.c. and the face layer is fastened with 1-5/8" Type S drywall screws spaced 12" o.c. Face layer end joints shall not occur on the same I-joist as base layer end joints and edge joints shall be offset 24" from base layer joints. Face layer to also be attached to base layer with 1-1/2" Type G drywall screws spaced 8" o.c. placed 6" from face layer end joints. Face layer wallboard joints to be taped and covered with joint compound. Minimum slab thickness — 1-hr: Varies". Minimum ceiling thickness — 1-hr: 1". Prescriptive assembly from the adopted building code — see table footnotes for conditions.
Wood I-joist (minimum I-joist depth 9-1/2" with a minimum flange depth of 1-5/16" and a minimum flange cross-sectional area of 1.95 square inches; minimum web thickness of 3/8") @ 24" o.c.. Ceiling: Minimum 0.019" thick resilient channel 16" o.c. (channels doubled at wallboard end joints), placed…
The full text is for BuildSpec members
Read the complete section, search across every adopted code, run the calculators and ask Copilot — free for 14 days, no card required.
- Layer-by-layer components with thicknesses
- Cross-section diagram
- Applicable code sections and test standard
- 6 related assemblies