IBC Design 721.1(3) 7-1.1

2-Hour Fire Rated Reinforced concrete slabs and joists with hollow clay… — 5/8" gypsum plaster on bottom of floor or…

IBC Table 721.1(3), Item 7-1.1: Reinforced concrete slabs and joists with hollow clay tile fillers laid end to end in rows 2-1/2" or more apart; reinforcement placed between rows and concrete cast around and over tile.. Ceiling: 5/8" gypsum plaster on bottom of floor or roof construction. Minimum slab thickness — 2-hr: 8". Minimum ceiling thickness — 2-hr: 5/8". Prescriptive assembly from the adopted building code — see table footnotes for conditions.

Reinforced concrete slabs and joists with hollow clay tile fillers laid end to end in rows 2-1/2" or more apart; reinforcement placed between rows and concrete cast around and over tile.. Ceiling: 5/8" gypsum plaster on bottom of floor or roof construction.

The rest of 2-Hour Fire Rated Reinforced concrete slabs and joists wi… is for members