IBC Table 721.1(3), Item 7-1.2: Reinforced concrete slabs and joists with hollow clay tile fillers laid end to end in rows 2-1/2" or more apart; reinforcement placed between rows and concrete cast around and over tile.. Ceiling: None Minimum slab thickness — 1-hr: 5-1/2". Prescriptive assembly from the adopted building code — see table footnotes for conditions.
Reinforced concrete slabs and joists with hollow clay tile fillers laid end to end in rows 2-1/2" or more apart; reinforcement placed between rows and concrete cast around and over tile.. Ceiling: None