IBC Design 721.1(1) 1-1.4

4-Hour Fire Rated Steel columns and all of primary trusses — Siliceous aggregate concrete and concrete excluded in Item…

IBC Table 721.1(1), Item 1-1.4 (Steel columns and all of primary trusses): protection by Siliceous aggregate concrete and concrete excluded in Item 1-1.1, members 6" x 6" or greater. Minimum insulating material thickness — 4-hr: 3" · 3-hr: 2" · 2-hr: 1-1/2" · 1-hr: 1". Prescriptive protection from the adopted building code — see table footnotes for conditions.

Siliceous aggregate concrete and concrete excluded in Item 1-1.1, members 6" x 6" or greater.

The full text is for BuildSpec members

Read the complete section, search across every adopted code, run the calculators and ask Copilot — free for 14 days, no card required.

  • Layer-by-layer components with thicknesses
  • Cross-section diagram
  • Applicable code sections and test standard
  • 6 related assemblies
Start your free 14-day trialSign in