IBC Design 721.1(1) 1-1.5
4-Hour Fire Rated Steel columns and all of primary trusses — Siliceous aggregate concrete and concrete excluded in Item…
IBC Table 721.1(1), Item 1-1.5 (Steel columns and all of primary trusses): protection by Siliceous aggregate concrete and concrete excluded in Item 1-1.1, members 8" x 8" or greater. Minimum insulating material thickness — 4-hr: 2-1/2" · 3-hr: 2" · 2-hr: 1" · 1-hr: 1". Prescriptive protection from the adopted building code — see table footnotes for conditions.
Siliceous aggregate concrete and concrete excluded in Item 1-1.1, members 8" x 8" or greater.