IBC Design 721.1(1) 1-3.1

4-Hour Fire Rated Steel columns and all of primary trusses — 4" hollow clay tile in two 2" layers; 1/2" mortar between…

IBC Table 721.1(1), Item 1-3.1 (Steel columns and all of primary trusses): protection by 4" hollow clay tile in two 2" layers; 1/2" mortar between tile and column; 3/8" metal mesh 0.046" wire diameter in horizontal joints; tile fill. Minimum insulating material thickness — 4-hr: 4". Prescriptive protection from the adopted building code — see table footnotes for conditions.

4" hollow clay tile in two 2" layers; 1/2" mortar between tile and column; 3/8" metal mesh 0.046" wire diameter in horizontal joints; tile fill.