IBC Design 721.1(1) 2-3.1

3-Hour Fire Rated Webs or flanges of steel beams and girders — Vermiculite gypsum plaster on a metal lath cage, wire tied…

IBC Table 721.1(1), Item 2-3.1 (Webs or flanges of steel beams and girders): protection by Vermiculite gypsum plaster on a metal lath cage, wire tied to 0.165" diameter (No. 8 B.W. gage) steel wire hangers wrapped around beam and spaced 16" on center. Metal lath ties spaced approximately 5" on center at cage sides and bottom. Minimum insulating material thickness — 3-hr: 7/8". Prescriptive protection from the adopted building code — see table footnotes for conditions.

Vermiculite gypsum plaster on a metal lath cage, wire tied to 0.165" diameter (No. 8 B.W. gage) steel wire hangers wrapped around beam and spaced 16" on center. Metal lath ties spaced approximately 5" on center at cage sides and bottom.

The full text is for BuildSpec members