IBC Design 721.1(1) 7-1.1

4-Hour Fire Rated Reinforcing and tie rods in floor and roof slabs — Carbonate, lightweight and sand-lightweight aggregate…

IBC Table 721.1(1), Item 7-1.1 (Reinforcing and tie rods in floor and roof slabs): protection by Carbonate, lightweight and sand-lightweight aggregate concrete Minimum insulating material thickness — 4-hr: 1" · 3-hr: 1" · 2-hr: 3/4" · 1-hr: 3/4". Prescriptive protection from the adopted building code — see table footnotes for conditions.

Carbonate, lightweight and sand-lightweight aggregate concrete