IBC Design 721.1(1) 7-1.2

4-Hour Fire Rated Reinforcing and tie rods in floor and roof slabs — Siliceous aggregate concrete

IBC Table 721.1(1), Item 7-1.2 (Reinforcing and tie rods in floor and roof slabs): protection by Siliceous aggregate concrete Minimum insulating material thickness — 4-hr: 1-1/4" · 3-hr: 1" · 2-hr: 1" · 1-hr: 3/4". Prescriptive protection from the adopted building code — see table footnotes for conditions.

Siliceous aggregate concrete

The full text is for BuildSpec members

Read the complete section, search across every adopted code, run the calculators and ask Copilot — free for 14 days, no card required.

  • Layer-by-layer components with thicknesses
  • Cross-section diagram
  • Applicable code sections and test standard
  • 6 related assemblies
Start your free 14-day trialSign in