KLH Design CLT 5-ply wall, exposed (2-hr tested)
2-Hour Fire Rated Mass Timber —
TESTED per ASTM E119 (Southwest Research Institute, 2/12/2020; documented in the WoodWorks Inventory of Fire Resistance-Tested Mass Timber Assemblies). Loaded 5-ply, 175 mm (6-7/8 in) KLH CV3M1 CLT wall with surface-spline panel joints and no protection on either side (exposed CLT); achieved 120 minutes of fire endurance, supporting a 2-hour rating. (Details per the cited source; confirm before specifying.)
TESTED per ASTM E119 (Southwest Research Institute, 2/12/2020; documented in the WoodWorks Inventory of Fire Resistance-Tested Mass Timber Assemblies). Loaded 5-ply, 175 mm (6-7/8 in) KLH CV3M1 CLT wall with surface-spline panel joints and no protection on either side (exposed CLT); achieved 120…