WoodWorks Design CLT exterior wall (NFPA 285 tested)

1-Hour Fire Rated Exterior Wall (NFPA 285) —

TESTED to NFPA 285 at Southwest Research Institute on April 28, 2022, and passed all criteria (WoodWorks Solution Paper 'CLT Exterior Wall Assemblies Meet NFPA 285'). Exterior wall of 3-ply, 4-1/8 in (105 mm) CLT with interior face exposed, faced outboard with 5/8 in Type X gypsum sheathing, a combustible WRB, and 2 in of 8 pcf mineral wool insulation; tested without cladding in a balloon-frame configuration. Note: NFPA 285 compliance is pass/fail for exterior fire propagation, not an hourly rating — the source does not state an hourly rating for this base wall, so 1 hour is a placeholder only.

TESTED to NFPA 285 at Southwest Research Institute on April 28, 2022, and passed all criteria (WoodWorks Solution Paper 'CLT Exterior Wall Assemblies Meet NFPA 285'). Exterior wall of 3-ply, 4-1/8 in (105 mm) CLT with interior face exposed, faced outboard with 5/8 in Type X gypsum sheathing, a…

The rest of 1-Hour Fire Rated Exterior Wall (NFPA 285) — is for members

You're reading the opening of 1-Hour Fire Rated Exterior Wall (NFPA 285) — . Members see the complete text, every cross-reference and the tools on this page — free for 14 days, no card required.

  • Layer-by-layer components with thicknesses
  • Cross-section diagram
  • Applicable code sections and test standard