UL Design U425

1-Hour Fire Rated Load-Bearing Steel Stud Wall — tested STC

UL Design U425 — load-bearing steel stud wall. 1-hour: one layer of 5/8" Type X each side with 3-1/2" insulation, tested STC 48 (OL12-0922). 2-hour: two layers of 5/8" Type X each side, tested STC 54 (OL12-0924). Per CertainTeed Fire Resistance and Sound Control Design Manual.

Load-bearing steel studs, 5/8" Type X each side, 3-1/2" insulation; STC 48 (1-hr) / 54 (2-hr)

The rest of 1-Hour Fire Rated Load-Bearing Steel Stud Wall — tested STC is for members