§ 238.425 — Electrical system
FRA Part 238 · Subpart E — Specific Requirements for Tier II Passenger Equipment. Full current text with cross-references on BuildSpec.
§ 238.425 Electrical system. (a) Circuit protection. (1) The main propulsion power line shall be protected with a lightning arrestor, automatic circuit breaker, and overload relay. The lightning arrestor shall be run by the most direct path possible to ground with a connection to ground of not less than No. 6 AWG. These overload protection devices shall be housed in an enclosure designed specifically for that purpose with the arc chute vented directly to outside air. (2) Head end power, including trainline power distribution, shall be provided with both overload and ground fault protection.…