29 CFR Part 1926

§ 1926.1409 — Power line safety (over 350 kV)

OSHA 1926 · Subpart CC — Cranes and Derricks in Construction. Full current text with cross-references on BuildSpec.

§ 1926.1409 Power line safety (over 350 kV). The requirements of §§ 1926.1407 and 1926.1408 apply to power lines over 350 kV except: (a) For power lines at or below 1000 kV, wherever the distance “20 feet” is specified, the distance “50 feet” must be substituted; and (b) For power lines over 1000 kV, the minimum clearance distance must be established by the utility owner/operator or registered professional engineer who is a qualified person with respect to electrical power transmission and distribution.

The rest of § 1926.1409 — Power line safety (over 350 kV) is for members

You're reading the opening of § 1926.1409 — Power line safety (over 350 kV). Members see the complete text, every cross-reference and the tools on this page — free for 14 days, no card required.

  • Full text of every OSHA 1926 section
  • Search across all federal and state standards in one place
  • Related sections, figures and tables
  • Ask Copilot about this section, with citations
Unlock § 1926.1409 — Power line safety (over 350 kV) — free for 14 daysSign in
OSHA 1926 1926.1409 — Power line safety (over 350 kV) | BuildSpec