Means of Egress · IBC 2021 §1023.2
Interior Exit Stairway Enclosure Ratings
Building sections: interior exit stairway enclosure rated 2 hr where connecting four stories or more, 1 hr for fewer; basements count, mezzanines do not; never below the floor assembly.. Referenced to IBC 2021 §1023.2.