Energy · IECC 2021 §R403.3.1
Supply and Return Duct Insulation
Supply and return ducts outside conditioned space need R-8 at 3 inches diameter and larger and R-6 below 3 inches; ducts buried beneath a building follow the same rule or a listed equivalent.. Referenced to IECC 2021 §R403.3.1.