GA FC42021-hr Fire RatingFloor/CeilingLoad-BearingSTC 47
Wood JoistDesign
GA Floor/Ceiling with Gypsum Board — 1-hr
Gypsum Association file FC4202 — 1-hour fire-rated floor-ceiling assembly.
Cross-Section Diagram
Legend
1Floor covering(varies)
23/4" OSB subfloor(3/4")
32x12 wood joists at 16" o.c.(9.25"-11.25")
45/8" Type C gypsum board(5/8")
Specifications
Fire Rating
1-Hour
STC Rating
STC 47
Load Bearing
Yes
Total Thickness
10.21"
Applicable Codes
IBC 2021 §722IRC R302.1
Construction Summary
GA file FC4202: Floor/Ceiling with Gypsum Board
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current GA Fire Resistance Design Manual database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.