Home / Assemblies / GA FC4204
GA FC42041.5-hr Fire RatingFloor/CeilingLoad-BearingSTC 40
Wood JoistDesign

GA Floor/Ceiling with Gypsum Board — 1.5-hr

Gypsum Association file FC4204 — 1.5-hour fire-rated floor-ceiling assembly.

Cross-Section Diagram

1234FLOOR/CEILING ASSEMBLYSECTION · NOT TO SCALE4 LAYERSsee legend for ① ② ③
Legend
1Floor covering(varies)
23/4" plywood subfloor(3/4")
32x10 wood joists at 16" o.c.(9.25"-11.25")
45/8" Type C gypsum board(5/8")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 40
Load Bearing
Yes
Total Thickness
10.5"
Source / Publisher
GA (Gypsum Association)
Design Number
FC4204
Assembly Type
Floor/Ceiling
Test Standard
ASTM E119
Construction Group
Light Frame
Number of Layers
4 layers

Applicable Codes

IBC 2021 Table 722.1IBC 2024 §722

Construction Summary

GA file FC4204: Floor/Ceiling with Gypsum Board

Material Layers

LayerMaterialThickness
1Floor coveringvaries
23/4" plywood subfloor3/4"
32x10 wood joists at 16" o.c.9.25"-11.25"
45/8" Type C gypsum board5/8"