GA SP22102-hr Fire RatingWallSTC 39
Steel StudMulti-Layer GypsumPartitionDesign
GA Steel Stud Partition — 2 layers 5/8" Type C
Gypsum Association file SP2210 — 2-hour fire-rated steel stud partition. GA file SP2210: 3-5/8" steel studs at 24" o.c., 2 layers of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
33-5/8" steel studs at 24" o.c.
45/8" Type C gypsum board(5/8")
55/8" Type C gypsum board(5/8")
Specifications
Fire Rating
2-Hour
STC Rating
STC 39
Load Bearing
No
Total Thickness
7.91"
Applicable Codes
IBC 2021 §722IBC 2021 Table 722.1
Construction Summary
GA file SP2210: 3-5/8" steel studs at 24" o.c., 2 layers of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current GA Fire Resistance Design Manual database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.