Home / Assemblies / GA SP2210
GA SP22102-hr Fire RatingWallSTC 39
Steel StudMulti-Layer GypsumPartitionDesign

GA Steel Stud Partition — 2 layers 5/8" Type C

Gypsum Association file SP2210 — 2-hour fire-rated steel stud partition. GA file SP2210: 3-5/8" steel studs at 24" o.c., 2 layers of 5/8" Type C gypsum board each side.

Cross-Section Diagram

123454.00"WALL ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
33-5/8" steel studs at 24" o.c.
45/8" Type C gypsum board(5/8")
55/8" Type C gypsum board(5/8")

Specifications

Fire Rating
2-Hour
STC Rating
STC 39
Load Bearing
No
Total Thickness
7.91"
Source / Publisher
GA (Gypsum Association)
Design Number
SP2210
Assembly Type
Wall
Test Standard
ASTM E119
Construction Group
Light Frame
Number of Layers
5 layers

Applicable Codes

IBC 2021 §722IBC 2021 Table 722.1

Construction Summary

GA file SP2210: 3-5/8" steel studs at 24" o.c., 2 layers of 5/8" Type C gypsum board each side

Material Layers

LayerMaterialThickness
15/8" Type C gypsum board5/8"
25/8" Type C gypsum board5/8"
33-5/8" steel studs at 24" o.c.
45/8" Type C gypsum board5/8"
55/8" Type C gypsum board5/8"

Important Notice