GA SP22153-hr Fire RatingWallLoad-BearingSTC 34
Steel StudMulti-Layer GypsumLoad-Bearing WallDesign
GA Steel Stud Partition — 3 layers 5/8" Type C
Gypsum Association file SP2215 — 3-hour fire-rated steel stud partition. GA file SP2215: 3-5/8" steel studs at 24" o.c., 3 layers of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
35/8" Type C gypsum board(5/8")
43-5/8" steel studs at 24" o.c.
55/8" Type C gypsum board(5/8")
65/8" Type C gypsum board(5/8")
75/8" Type C gypsum board(5/8")
Specifications
Fire Rating
3-Hour
STC Rating
STC 34
Load Bearing
Yes
Total Thickness
7.51"
Applicable Codes
IBC 2021 Table 722.1IRC R302.1
Construction Summary
GA file SP2215: 3-5/8" steel studs at 24" o.c., 3 layers of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current GA Fire Resistance Design Manual database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.