GA WP12061.5-hr Fire RatingWallLoad-BearingSTC 37
Steel StudGypsum BoardLoad-Bearing WallDesign
GA Wood Stud Partition — 1 layer 5/8" Type C
Gypsum Association file WP1206 — 1.5-hour fire-rated wood stud partition. GA file WP1206: 3-5/8" steel studs at 24" o.c., 1 layer of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
23-5/8" steel studs at 24" o.c.
35/8" Type C gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 37
Load Bearing
Yes
Total Thickness
6"
Applicable Codes
IBC 2024 §722NFPA 5000
Construction Summary
GA file WP1206: 3-5/8" steel studs at 24" o.c., 1 layer of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current GA Fire Resistance Design Manual database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.