UL D1051.5-hr Fire RatingFloor/CeilingLoad-BearingSTC 35
Steel JoistFiberglass BattDesign
Steel Joist Floor/Ceiling — single layer Spray-applied fireproofing
UL-listed 1.5-hour fire-rated steel joist floor/ceiling assembly. Open-web steel joists at 24" o.c. with R-19 fiberglass batt, single layer of Spray-applied fireproofing ceiling.
Cross-Section Diagram
Legend
1Floor covering(varies)
22" concrete on steel deck(2")
3Open-web steel joists at 24" o.c.(14.0")
4R-19 fiberglass batt
5Spray-applied fireproofing(1-1/2")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 35
Load Bearing
Yes
Total Thickness
17"
Applicable Codes
IBC 2021 Table 722.1IBC 2021 §722IBC 2024 Table 722.1
Construction Summary
Open-web steel joists at 24" o.c. with R-19 fiberglass batt, single layer of Spray-applied fireproofing ceiling
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.