Home / Assemblies / UL G116
UL G1161.5-hr Fire RatingColumnLoad-Bearing
Design

Wood Column — Gypsum board enclosure

UL-listed 1.5-hour fire-rated wood column assembly. Glulam column with Gypsum board enclosure, 1.5-hour fire rating.

Cross-Section Diagram

12COLUMN PROTECTIONSECTION · NOT TO SCALE2 LAYERSsee legend for ① ② ③
Legend
1Glulam column(7")
2Gypsum board enclosure(0.94")

Specifications

Fire Rating
1.5-Hour
Load Bearing
Yes
Total Thickness
8.88"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
G116
Assembly Type
Column
Test Standard
CAN/ULC-S101
Construction Group
Non-Combustible
Number of Layers
2 layers

Applicable Codes

IBC 2021 §722IBC 2024 §722

Construction Summary

Glulam column with Gypsum board enclosure, 1.5-hour fire rating

Material Layers

LayerMaterialThickness
1Glulam column7"
2Gypsum board enclosure0.94"

Important Notice