UL J1193-hr Fire RatingJoint System
Mineral WoolDesign
Perimeter Fire Barrier Joint — Intumescent System
UL-listed 3-hour fire-rated perimeter fire barrier joint system. Perimeter Fire Barrier Joint, 1" max width, Intumescent wrap strip with mineral wool backer.
Cross-Section Diagram
Legend
1Mineral wool backer(2")
2Intumescent wrap strip(5/8")
Specifications
Fire Rating
3-Hour
Load Bearing
No
Total Thickness
Varies
Applicable Codes
IBC 2024 §714IBC 2021 §715
Construction Summary
Perimeter Fire Barrier Joint, 1" max width, Intumescent wrap strip with mineral wool backer
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.