UL L1161.5-hr Fire RatingRoof/CeilingLoad-Bearing
Wood JoistGypsum BoardFiberglass BattDesign
Wood Truss Roof/Ceiling — 2 layers 5/8" Type X gypsum board
UL-listed 1.5-hour fire-rated wood truss roof/ceiling assembly. Wood trusses at 16" o.c. with R-38 blown fiberglass, 2 layers of 5/8" Type X gypsum board ceiling, 7/16" OSB sheathing.
Cross-Section Diagram
Legend
1Roof covering(varies)
27/16" OSB sheathing(7/16")
3Wood trusses at 16" o.c.(12"-24")
4R-38 blown fiberglass
55/8" Type X gypsum board(5/8")
65/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
Load Bearing
Yes
Total Thickness
15.25"
Applicable Codes
IBC 2021 §722
Construction Summary
Wood trusses at 16" o.c. with R-38 blown fiberglass, 2 layers of 5/8" Type X gypsum board ceiling, 7/16" OSB sheathing
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.