Home / Assemblies / UL L127
UL L1271.5-hr Fire RatingRoof/CeilingLoad-Bearing
Fiberglass BattDesign

Wood Truss Roof/Ceiling — single layer 5/8" Type C gypsum board

UL-listed 1.5-hour fire-rated wood truss roof/ceiling assembly. 2x10 wood rafters at 16" o.c. with R-30 fiberglass batt, single layer of 5/8" Type C gypsum board ceiling, 1/2" plywood sheathing.

Cross-Section Diagram

12345ROOF/CEILING ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
1Roof covering(varies)
21/2" plywood sheathing(1/2")
32x10 wood rafters at 16" o.c.(12"-24")
4R-30 fiberglass batt
55/8" Type C gypsum board(5/8")

Specifications

Fire Rating
1.5-Hour
Load Bearing
Yes
Total Thickness
14.62"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
L127
Assembly Type
Roof/Ceiling
Test Standard
CAN/ULC-S101
Construction Group
Light Frame
Number of Layers
5 layers

Applicable Codes

IBC 2021 §722IBC 2021 Table 722.1

Construction Summary

2x10 wood rafters at 16" o.c. with R-30 fiberglass batt, single layer of 5/8" Type C gypsum board ceiling, 1/2" plywood sheathing

Material Layers

LayerMaterialThickness
1Roof coveringvaries
21/2" plywood sheathing1/2"
32x10 wood rafters at 16" o.c.12"-24"
4R-30 fiberglass batt
55/8" Type C gypsum board5/8"

Important Notice