UL L1803-hr Fire RatingRoof/CeilingLoad-Bearing
Steel StudGypsum BoardDesign

Steel Truss Roof/Ceiling — 2 layers 5/8" Type X gypsum board

UL-listed 3-hour fire-rated steel truss roof/ceiling assembly. Light gauge steel trusses at 24" o.c. with Rigid insulation board, 2 layers of 5/8" Type X gypsum board on furring channels ceiling, 22 ga. steel deck.

Cross-Section Diagram

123456ROOF/CEILING ASSEMBLYSECTION · NOT TO SCALE6 LAYERSsee legend for ① ② ③
Legend
1Roof covering(varies)
222 ga. steel deck(varies)
3Light gauge steel trusses at 24" o.c.(12"-24")
4Rigid insulation board
55/8" Type X gypsum board on furring channels(5/8")
65/8" Type X gypsum board on furring channels(5/8")

Specifications

Fire Rating
3-Hour
Load Bearing
Yes
Total Thickness
15.25"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
L180
Assembly Type
Roof/Ceiling
Test Standard
UL 263
Construction Group
Non-Combustible
Number of Layers
6 layers

Applicable Codes

IBC 2021 §722IBC 2021 Table 722.1

Construction Summary

Light gauge steel trusses at 24" o.c. with Rigid insulation board, 2 layers of 5/8" Type X gypsum board on furring channels ceiling, 22 ga. steel deck

Material Layers

LayerMaterialThickness
1Roof coveringvaries
222 ga. steel deckvaries
3Light gauge steel trusses at 24" o.c.12"-24"
4Rigid insulation board
55/8" Type X gypsum board on furring channels5/8"
65/8" Type X gypsum board on furring channels5/8"

Important Notice