Home / Assemblies / UL N156
UL N1561-hr Fire RatingColumnLoad-Bearing
ConcreteDesign

Concrete Column — Spray-applied fireproofing

UL-listed 1-hour fire-rated concrete column assembly. Precast concrete column with Spray-applied fireproofing, 1-hour fire rating.

Cross-Section Diagram

12COLUMN PROTECTIONSECTION · NOT TO SCALE2 LAYERSsee legend for ① ② ③
Legend
1Precast concrete column(11")
2Spray-applied fireproofing(0.62")

Specifications

Fire Rating
1-Hour
Load Bearing
Yes
Total Thickness
12.24"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
N156
Assembly Type
Column
Test Standard
UL 263
Construction Group
Concrete/Masonry
Number of Layers
2 layers

Applicable Codes

IBC 2021 §722NFPA 5000

Construction Summary

Precast concrete column with Spray-applied fireproofing, 1-hour fire rating

Material Layers

LayerMaterialThickness
1Precast concrete column11"
2Spray-applied fireproofing0.62"

Important Notice

This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.