B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Home / Assemblies / UL U142
UL U1424-hr Fire RatingWallLoad-BearingSTC 47
Wood StudMulti-Layer GypsumFiberglass BattLoad-Bearing WallDesign

Wood Stud Wall — 3 layers 5/8" Type X

UL-listed 4-hour fire-rated wood stud wall assembly. 2x4 wood studs at 24" o.c. with R-13 fiberglass batt, 3 layers of 5/8" Type X gypsum board each side.

Cross-Section Diagram

123456788.75"WALL ASSEMBLYSECTION · NOT TO SCALE8 LAYERSsee legend for ① ② ③
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
35/8" Type X gypsum board(5/8")
42x4 wood studs at 24" o.c.(3.5")
5R-13 fiberglass batt
65/8" Type X gypsum board(5/8")
75/8" Type X gypsum board(5/8")
85/8" Type X gypsum board(5/8")

Specifications

Fire Rating
4-Hour
STC Rating
STC 47
Load Bearing
Yes
Total Thickness
7.25"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U142
Assembly Type
Wall
Test Standard
CAN/ULC-S101
Construction Group
Light Frame
Number of Layers
8 layers

Applicable Codes

IBC 2021 Table 722.1IBC 2024 §722IRC R302.1

Construction Summary

2x4 wood studs at 24" o.c. with R-13 fiberglass batt, 3 layers of 5/8" Type X gypsum board each side

Material Layers

LayerMaterialThickness
15/8" Type X gypsum board5/8"
25/8" Type X gypsum board5/8"
35/8" Type X gypsum board5/8"
42x4 wood studs at 24" o.c.3.5"
5R-13 fiberglass batt
65/8" Type X gypsum board5/8"
75/8" Type X gypsum board5/8"
85/8" Type X gypsum board5/8"

Important Notice