Home / Assemblies / UL U152
UL U1521.5-hr Fire RatingWallLoad-BearingSTC 44
Wood StudGypsum BoardMineral WoolLoad-Bearing WallDesign

Wood Stud Wall — single layer 1/2" Type X

UL-listed 1.5-hour fire-rated wood stud wall assembly. 2x6 wood studs at 16" o.c. with R-15 mineral wool batt, single layer of 1/2" Type X gypsum board each side.

Cross-Section Diagram

12348.00"WALL ASSEMBLYSECTION · NOT TO SCALE4 LAYERSsee legend for ① ② ③
Legend
11/2" Type X gypsum board(1/2")
22x6 wood studs at 16" o.c.(5.5")
3R-15 mineral wool batt
41/2" Type X gypsum board(1/2")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 44
Load Bearing
Yes
Total Thickness
6.5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U152
Assembly Type
Wall
Test Standard
UL 263
Construction Group
Light Frame
Number of Layers
4 layers

Applicable Codes

IBC 2021 §722IBC 2024 §722

Construction Summary

2x6 wood studs at 16" o.c. with R-15 mineral wool batt, single layer of 1/2" Type X gypsum board each side

Material Layers

LayerMaterialThickness
11/2" Type X gypsum board1/2"
22x6 wood studs at 16" o.c.5.5"
3R-15 mineral wool batt
41/2" Type X gypsum board1/2"

Important Notice