Home / Assemblies / UL U180
UL U1801.5-hr Fire RatingWallLoad-BearingSTC 65
Wood StudMulti-Layer GypsumFiberglass BattResilient ChannelLoad-Bearing WallHigh STCDesign

Wood Stud Wall — 2 layers 5/8" Type C on resilient channels

UL-listed 1.5-hour fire-rated wood stud wall assembly. 2x6 wood studs at 24" o.c. with R-13 fiberglass batt, 2 layers of 5/8" Type C gypsum board each side on resilient channels.

Cross-Section Diagram

123456710.38"WALL ASSEMBLYSECTION · NOT TO SCALE7 LAYERSsee legend for ① ② ③
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
3Resilient channels at 24" o.c.(7/8")
42x6 wood studs at 24" o.c.(5.5")
5R-13 fiberglass batt
65/8" Type C gypsum board(5/8")
75/8" Type C gypsum board(5/8")

Specifications

Fire Rating
1.5-Hour
STC Rating
STC 65
Load Bearing
Yes
Total Thickness
8.875"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U180
Assembly Type
Wall
Test Standard
ASTM E119
Construction Group
Light Frame
Number of Layers
7 layers

Applicable Codes

IBC 2021 Table 722.1

Construction Summary

2x6 wood studs at 24" o.c. with R-13 fiberglass batt, 2 layers of 5/8" Type C gypsum board each side on resilient channels

Material Layers

LayerMaterialThickness
15/8" Type C gypsum board5/8"
25/8" Type C gypsum board5/8"
3Resilient channels at 24" o.c.7/8"
42x6 wood studs at 24" o.c.5.5"
5R-13 fiberglass batt
65/8" Type C gypsum board5/8"
75/8" Type C gypsum board5/8"