UL U1934-hr Fire RatingWallLoad-BearingSTC 69
Wood StudMulti-Layer GypsumMineral WoolResilient ChannelLoad-Bearing WallHigh STCDesign
Wood Stud Wall — 4 layers 5/8" Type X on resilient channels
UL-listed 4-hour fire-rated wood stud wall assembly. 2x6 wood studs at 24" o.c. with R-21 mineral wool batt, 4 layers of 5/8" Type X gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
35/8" Type X gypsum board(5/8")
45/8" Type X gypsum board(5/8")
5Resilient channels at 24" o.c.(7/8")
62x6 wood studs at 24" o.c.(5.5")
7R-21 mineral wool batt
85/8" Type X gypsum board(5/8")
95/8" Type X gypsum board(5/8")
105/8" Type X gypsum board(5/8")
115/8" Type X gypsum board(5/8")
Specifications
Fire Rating
4-Hour
STC Rating
STC 69
Load Bearing
Yes
Total Thickness
11.375"
Applicable Codes
IBC 2021 Table 722.1IBC 2024 §722
Construction Summary
2x6 wood studs at 24" o.c. with R-21 mineral wool batt, 4 layers of 5/8" Type X gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.