UL U2211-hr Fire RatingWallSTC 45
Steel StudGypsum BoardFiberglass BattPartitionDesign
Steel Stud Wall — single layer 5/8" Type C
UL-listed 1-hour fire-rated steel stud wall assembly. 3-5/8" steel studs at 16" o.c. with R-19 fiberglass batt, single layer of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
23-5/8" steel studs at 16" o.c.(3.625")
3R-19 fiberglass batt
45/8" Type C gypsum board(5/8")
Specifications
Fire Rating
1-Hour
STC Rating
STC 45
Load Bearing
No
Total Thickness
4.875"
Applicable Codes
IBC 2021 §722IBC 2024 §722IRC R302.1
Construction Summary
3-5/8" steel studs at 16" o.c. with R-19 fiberglass batt, single layer of 5/8" Type C gypsum board each side
Material Layers