Home / Assemblies / UL U288
UL U2884-hr Fire RatingWallSTC 55
Steel StudMulti-Layer GypsumFiberglass BattPartitionHigh STCDesign

Steel Stud Wall — 3 layers 1/2" Type X

UL-listed 4-hour fire-rated steel stud wall assembly. 6" steel studs at 24" o.c. with R-11 fiberglass batt, 3 layers of 1/2" Type X gypsum board each side.

Cross-Section Diagram

1234567810.50"WALL ASSEMBLYSECTION · NOT TO SCALE8 LAYERSsee legend for ① ② ③
Legend
11/2" Type X gypsum board(1/2")
21/2" Type X gypsum board(1/2")
31/2" Type X gypsum board(1/2")
46" steel studs at 24" o.c.(6.0")
5R-11 fiberglass batt
61/2" Type X gypsum board(1/2")
71/2" Type X gypsum board(1/2")
81/2" Type X gypsum board(1/2")

Specifications

Fire Rating
4-Hour
STC Rating
STC 55
Load Bearing
No
Total Thickness
9"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U288
Assembly Type
Wall
Test Standard
ASTM E119
Construction Group
Light Frame
Number of Layers
8 layers

Applicable Codes

IRC R302.1

Construction Summary

6" steel studs at 24" o.c. with R-11 fiberglass batt, 3 layers of 1/2" Type X gypsum board each side

Material Layers

LayerMaterialThickness
11/2" Type X gypsum board1/2"
21/2" Type X gypsum board1/2"
31/2" Type X gypsum board1/2"
46" steel studs at 24" o.c.6.0"
5R-11 fiberglass batt
61/2" Type X gypsum board1/2"
71/2" Type X gypsum board1/2"
81/2" Type X gypsum board1/2"