UL U3022-hr Fire RatingWallSTC 48
Steel StudMulti-Layer GypsumPartitionDesign

Steel Stud Wall — 2 layers 5/8" Type C

UL-listed 2-hour fire-rated steel stud wall assembly. 6" steel studs at 16" o.c., 2 layers of 5/8" Type C gypsum board each side.

Cross-Section Diagram

123458.50"WALL ASSEMBLYSECTION · NOT TO SCALE5 LAYERSsee legend for ① ② ③
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
36" steel studs at 16" o.c.(6.0")
45/8" Type C gypsum board(5/8")
55/8" Type C gypsum board(5/8")

Specifications

Fire Rating
2-Hour
STC Rating
STC 48
Load Bearing
No
Total Thickness
8.5"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
U302
Assembly Type
Wall
Test Standard
CAN/ULC-S101
Construction Group
Light Frame
Number of Layers
5 layers

Applicable Codes

IBC 2021 §722IRC R302.1

Construction Summary

6" steel studs at 16" o.c., 2 layers of 5/8" Type C gypsum board each side

Material Layers

LayerMaterialThickness
15/8" Type C gypsum board5/8"
25/8" Type C gypsum board5/8"
36" steel studs at 16" o.c.6.0"
45/8" Type C gypsum board5/8"
55/8" Type C gypsum board5/8"

Important Notice