UL U3171-hr Fire RatingWallSTC 45
Steel StudGypsum BoardMineral WoolPartitionDesign
Shaft Wall — single layer 1" Type C
UL-listed 1-hour fire-rated shaft wall assembly. 2-1/2" CT studs at 24" o.c. with R-8 mineral wool, single layer of 1" Shaftliner gypsum board each side.
Cross-Section Diagram
Legend
11" Shaftliner gypsum board(1")
22-1/2" CT studs at 24" o.c.(2.5")
3R-8 mineral wool
41" Shaftliner gypsum board(1")
Specifications
Fire Rating
1-Hour
STC Rating
STC 45
Load Bearing
No
Total Thickness
4.5"
Applicable Codes
IBC 2021 Table 722.1IBC 2021 §722IBC 2024 Table 722.1
Construction Summary
2-1/2" CT studs at 24" o.c. with R-8 mineral wool, single layer of 1" Shaftliner gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.