UL U3304-hr Fire RatingWallSTC 64
Steel StudMulti-Layer GypsumMineral WoolResilient ChannelPartitionHigh STCDesign
Shaft Wall — 3 layers 5/8" Type X on resilient channels
UL-listed 4-hour fire-rated shaft wall assembly. 2-1/2" CT studs at 24" o.c. with R-8 mineral wool, 3 layers of 5/8" Type X gypsum board each side on resilient channels.
Cross-Section Diagram
Legend
15/8" Type X gypsum board(5/8")
25/8" Type X gypsum board(5/8")
35/8" Type X gypsum board(5/8")
4Resilient channels at 24" o.c.(7/8")
52-1/2" CT studs at 24" o.c.(2.5")
6R-8 mineral wool
75/8" Type X gypsum board(5/8")
85/8" Type X gypsum board(5/8")
95/8" Type X gypsum board(5/8")
Specifications
Fire Rating
4-Hour
STC Rating
STC 64
Load Bearing
No
Total Thickness
7.125"
Applicable Codes
IBC 2024 Table 722.1IRC R302.1
Construction Summary
2-1/2" CT studs at 24" o.c. with R-8 mineral wool, 3 layers of 5/8" Type X gypsum board each side on resilient channels
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.