UL W1273-hr Fire RatingFloor/CeilingLoad-BearingSTC 46
Wood JoistGypsum BoardFiberglass BattDesign

Wood Joist Floor/Ceiling — 3 layers 5/8" Type C gypsum board

UL-listed 3-hour fire-rated wood joist floor/ceiling assembly. 2x12 wood joists at 16" o.c. with R-30 fiberglass batt, 3 layers of 5/8" Type C gypsum board ceiling.

Cross-Section Diagram

1234567FLOOR/CEILING ASSEMBLYSECTION · NOT TO SCALE7 LAYERSsee legend for ① ② ③
Legend
1Floor covering(varies)
21-1/8" T&G plywood subfloor(1-1/8")
32x12 wood joists at 16" o.c.(11.25")
4R-30 fiberglass batt
55/8" Type C gypsum board(5/8")
65/8" Type C gypsum board(5/8")
75/8" Type C gypsum board(5/8")

Specifications

Fire Rating
3-Hour
STC Rating
STC 46
Load Bearing
Yes
Total Thickness
14.62"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
W127
Assembly Type
Floor/Ceiling
Test Standard
CAN/ULC-S101
Construction Group
Light Frame
Number of Layers
7 layers

Applicable Codes

IBC 2021 Table 722.1IBC 2024 §722

Construction Summary

2x12 wood joists at 16" o.c. with R-30 fiberglass batt, 3 layers of 5/8" Type C gypsum board ceiling

Material Layers

LayerMaterialThickness
1Floor coveringvaries
21-1/8" T&G plywood subfloor1-1/8"
32x12 wood joists at 16" o.c.11.25"
4R-30 fiberglass batt
55/8" Type C gypsum board5/8"
65/8" Type C gypsum board5/8"
75/8" Type C gypsum board5/8"