UL W1321-hr Fire RatingFloor/CeilingLoad-BearingSTC 53
Wood JoistMineral WoolDesign
Wood Joist Floor/Ceiling — single layer 5/8" Type X gypsum board
UL-listed 1-hour fire-rated wood joist floor/ceiling assembly. TJI wood I-joists at 16" o.c. with R-30 mineral wool, single layer of 5/8" Type X gypsum board ceiling.
Cross-Section Diagram
Legend
1Floor covering(varies)
21-1/8" T&G plywood subfloor(1-1/8")
3TJI wood I-joists at 16" o.c.(11.875")
4R-30 mineral wool
55/8" Type X gypsum board(5/8")
Specifications
Fire Rating
1-Hour
STC Rating
STC 53
Load Bearing
Yes
Total Thickness
14"
Applicable Codes
IBC 2021 Table 722.1IBC 2024 Table 722.1IRC R302.1
Construction Summary
TJI wood I-joists at 16" o.c. with R-30 mineral wool, single layer of 5/8" Type X gypsum board ceiling
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.