Home / Assemblies / UL W163
UL W1634-hr Fire RatingFloor/CeilingLoad-BearingSTC 49
Wood JoistMulti-Layer GypsumMineral WoolDesign

Wood Joist Floor/Ceiling — 4 layers 5/8" Type C gypsum board

UL-listed 4-hour fire-rated wood joist floor/ceiling assembly. TJI wood I-joists at 24" o.c. with R-30 mineral wool, 4 layers of 5/8" Type C gypsum board ceiling.

Cross-Section Diagram

12345678FLOOR/CEILING ASSEMBLYSECTION · NOT TO SCALE8 LAYERSsee legend for ① ② ③
Legend
1Floor covering(varies)
21-1/8" T&G plywood subfloor(1-1/8")
3TJI wood I-joists at 24" o.c.(11.875")
4R-30 mineral wool
55/8" Type C gypsum board(5/8")
65/8" Type C gypsum board(5/8")
75/8" Type C gypsum board(5/8")
85/8" Type C gypsum board(5/8")

Specifications

Fire Rating
4-Hour
STC Rating
STC 49
Load Bearing
Yes
Total Thickness
15.88"
Source / Publisher
UL (Underwriters Laboratories)
Design Number
W163
Assembly Type
Floor/Ceiling
Test Standard
UL 263
Construction Group
Light Frame
Number of Layers
8 layers

Applicable Codes

IBC 2021 Table 722.1IBC 2024 Table 722.1IRC R302.1

Construction Summary

TJI wood I-joists at 24" o.c. with R-30 mineral wool, 4 layers of 5/8" Type C gypsum board ceiling

Material Layers

LayerMaterialThickness
1Floor coveringvaries
21-1/8" T&G plywood subfloor1-1/8"
3TJI wood I-joists at 24" o.c.11.875"
4R-30 mineral wool
55/8" Type C gypsum board5/8"
65/8" Type C gypsum board5/8"
75/8" Type C gypsum board5/8"
85/8" Type C gypsum board5/8"