UL X2743-hr Fire RatingColumnLoad-Bearing
Structural SteelDesign
Steel Column — Spray-applied cementitious fireproofing
UL-listed 3-hour fire-rated steel column assembly. HSS round steel column with Spray-applied cementitious fireproofing, 3-hour fire rating.
Cross-Section Diagram
Legend
1HSS round steel column(8")
2Spray-applied cementitious fireproofing(1.86")
Specifications
Fire Rating
3-Hour
Load Bearing
Yes
Total Thickness
11.72"
Applicable Codes
IBC 2024 §722IBC 2021 §722
Construction Summary
HSS round steel column with Spray-applied cementitious fireproofing, 3-hour fire rating
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.