UL X2962-hr Fire RatingColumnLoad-Bearing
Structural SteelDesign
Steel Column — Spray-applied cementitious fireproofing
UL-listed 2-hour fire-rated steel column assembly. HSS rectangular steel column with Spray-applied cementitious fireproofing, 2-hour fire rating.
Cross-Section Diagram
Legend
1HSS rectangular steel column(7")
2Spray-applied cementitious fireproofing(1.25")
Specifications
Fire Rating
2-Hour
Load Bearing
Yes
Total Thickness
9.5"
Applicable Codes
IBC 2021 §722NFPA 5000
Construction Summary
HSS rectangular steel column with Spray-applied cementitious fireproofing, 2-hour fire rating
Material Layers