UL X3201.5-hr Fire RatingColumnLoad-Bearing
Design
Steel Column — Intumescent coating
UL-listed 1.5-hour fire-rated steel column assembly. Steel pipe column with Intumescent coating, 1.5-hour fire rating.
Cross-Section Diagram
Legend
1Steel pipe column(11")
2Intumescent coating(0.095")
Specifications
Fire Rating
1.5-Hour
Load Bearing
Yes
Total Thickness
11.19"
Applicable Codes
IBC 2021 §722NFPA 5000
Construction Summary
Steel pipe column with Intumescent coating, 1.5-hour fire rating
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current UL Product iQ database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.