GA SP22041.5-hr Fire RatingWallSTC 44
Wood StudMulti-Layer GypsumPartitionDesign
GA Steel Stud Partition — 2 layers 5/8" Type C
Gypsum Association file SP2204 — 1.5-hour fire-rated steel stud partition. GA file SP2204: 2x4 wood studs at 16" o.c., 2 layers of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
25/8" Type C gypsum board(5/8")
32x4 wood studs at 16" o.c.
45/8" Type C gypsum board(5/8")
55/8" Type C gypsum board(5/8")
Specifications
Fire Rating
1.5-Hour
STC Rating
STC 44
Load Bearing
No
Total Thickness
5.98"
Applicable Codes
NFPA 5000IBC 2024 §722
Construction Summary
GA file SP2204: 2x4 wood studs at 16" o.c., 2 layers of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current GA Fire Resistance Design Manual database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.