GA WP12001-hr Fire RatingWallLoad-BearingSTC 40
Wood StudGypsum BoardLoad-Bearing WallDesign
GA Wood Stud Partition — 1 layer 5/8" Type C
Gypsum Association file WP1200 — 1-hour fire-rated wood stud partition. GA file WP1200: 2x4 wood studs at 16" o.c., 1 layer of 5/8" Type C gypsum board each side.
Cross-Section Diagram
Legend
15/8" Type C gypsum board(5/8")
22x4 wood studs at 16" o.c.
35/8" Type C gypsum board(5/8")
Specifications
Fire Rating
1-Hour
STC Rating
STC 40
Load Bearing
Yes
Total Thickness
5.74"
Applicable Codes
IBC 2021 Table 722.1IBC 2024 Table 722.1
Construction Summary
GA file WP1200: 2x4 wood studs at 16" o.c., 1 layer of 5/8" Type C gypsum board each side
Material Layers
Important Notice
This assembly listing is for reference only. Always verify against the current GA Fire Resistance Design Manual database before specifying in construction documents. Material substitutions may void the fire rating. Consult with a qualified fire protection engineer for project-specific requirements.