Home / Assemblies / GA WP1201
GA WP12011-hr Fire RatingWallLoad-BearingSTC 39
Steel StudGypsum BoardLoad-Bearing WallDesign

GA Wood Stud Partition — 1 layer 5/8" Type X

Gypsum Association file WP1201 — 1-hour fire-rated wood stud partition. GA file WP1201: 3-5/8" steel studs at 24" o.c., 1 layer of 5/8" Type X gypsum board each side.

Cross-Section Diagram

1232.75"WALL ASSEMBLYSECTION · NOT TO SCALE3 LAYERSsee legend for ① ② ③
Legend
15/8" Type X gypsum board(5/8")
23-5/8" steel studs at 24" o.c.
35/8" Type X gypsum board(5/8")

Specifications

Fire Rating
1-Hour
STC Rating
STC 39
Load Bearing
Yes
Total Thickness
4.31"
Source / Publisher
GA (Gypsum Association)
Design Number
WP1201
Assembly Type
Wall
Test Standard
ASTM E119
Construction Group
Light Frame
Number of Layers
3 layers

Applicable Codes

NFPA 5000IBC 2024 §722

Construction Summary

GA file WP1201: 3-5/8" steel studs at 24" o.c., 1 layer of 5/8" Type X gypsum board each side

Material Layers

LayerMaterialThickness
15/8" Type X gypsum board5/8"
23-5/8" steel studs at 24" o.c.
35/8" Type X gypsum board5/8"

Important Notice